KYORITSU
KYORITSU
Showing 73–84 of 91 results
-
KEW5406A
Read more• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD’s: Standard, Selective, AC and A (DC sensitive breakers) -
KEW5410
Read more• Measurement of RCD trip time
 Conducting testing of rated residual non-operating currents at
 × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
 Measuring trip out current by varying current automatically.
• Remote Test
 Enabling a user to hold the Test Leads with his both hands
 by locking the Test Button. Measurement will automatically
 start when the main voltage is detected.
• Voltage Measurement
 Carrying out a constant measurement of voltage in the
 stand-by mode at each Range.
• Auto-detection of Contact voltage
 Detecting the voltage to earth of Earth electrodes or
 Protective conductors during RCD test – when applying
 test currents – at measurement using EARTH in order to
 prevent electrical shocks caused by the damaged earth.
 Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
 Dust- and Water-proof construction
 (designed to IEC 60529 IP54).
• Backlight
 Facilitating working at dimly illuminated locations. -
KEW6010B
Read more• Continuity:20/200Ω 200mA Test Current
• Insulation: 500/1000V, 20/200MΩ 1mA Rated Test Current
• Loop Impedance:20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
• RCD:10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
• Test of a large kind of RCD’s:Standard, Selective, AC and A(DC sensitive breakers)
• Uc(Contact Voltage): 100V
• Designed to IEC 61010-1, IEC 61557
• Data Memory:300 measured results
• The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C. -
KEW6011A
Read more• Complies with IEC 61557
• Designed to IP 54 Rating
• Live circuit and wiring connection check LED’s
• Triple ranges insulation tests at 250, 500 and 1000V
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip)
• Phase angle selection on RCD ranges
• Polarity switch for continuity tests
• Auto-null facility for continuity tests
• Earth probe for loop impedance testing on extraneous metalwork
• Contact Voltage Reading
• Test of a large kind of RCD’s: Standard, Selective, AC and A
(DC sensitive breakers) -
KEW6205
Read moreProtect life and property from faulty appliances
・Battery operated
・PASS / FAIL result
・Color status back light
・10 mA & 30 mA RCD test(Isolation transformer built in)
 Memory function up to 999 data
・Printer output
・Complies to AS / NZS 3760This instrument is suitable for performing tests as required by the following standards.
AS/NZS 3760 In-service safety inspection and testing of electrical equipment. -
KEW6305
Read more• Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
• Voltage, Current, Power Factor and Frequency measurements
• Power analysis (Active, Apparent and Reactive power)
• Energy analysis (Active, Apparent and Reactive power)
• Active power accuracy: ±0.3%rdg±0.2%f.s.
• Automatic wiring check function to prevent incorrect connections
• Large memory capability (2GB) using built-in SD card interface
• Real time & remote measurements using Android application
• synchronous measurements between two units of KEW 6305
• Wide selection of clamp sensors allow measurements from 0.1A to 3000A
• The instrument automatically recognizes what kind of clamp sensor is connected to it
• Windows software for data analysis and setting via USB port or Bluetooth -
KEW6315
Read more• Simultaneous Power & Power quality measurements
• Helpful support functions
• Measurement with high accuracy
• Remote monitoring on PC and Android device
• Various Clamp Current Sensors
• Energy consumption check on site
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V
• Simultaneous Power & Power quality measurements
oPower/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch)
• Helpful support functions
oQuick Start Guide, Wiring check and Sensor detection for easy and reliable measurement
• Measurement with high accuracy
oGuaranteed accuracy:±0.3%rdg (energy),±0.2%rdg (voltage/ current)
Complies with the International Standard IEC 61000-4-30 Class S and the European Standard EN50160
• Remote monitoring on PC and Android device
oRemote checking of measurement in real-time is possible via Bluetooth communication.
oRecorded data can be saved in the supplied SD card.
oEN50160 report can be generated after survey by PC software.
• Various Clamp Current Sensors
oVarious types of clamp and flexible sensors are available:
from 1000mA Range up to 3000A Range and Earth leakage measurements
oEnergy consumption check on site
Trend and demand graphs for easy recognition.
TFT color display with high resolution.
• IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V -
KEW6516
Read moreDISPLAY         ・Color LCD 3.5 inches dot matrix.
ATT             ・Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
                ・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOP            ・High test current range of 2Ω with 0.001Ω resolution.
                ・Zs Limit compares the values required by Electrical Installations Standard with
                 measured results.
RCD             ・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
                ・Single and Auto test, Ramp test and Contact voltage.
EARTH           ・Earth resistance test 2 and 3 wires with all accessories included.
INSULATION      ・Resistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITY     ・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATION ・On 3-phase lines with clear indication of the sequence on the display.
VOLTS           ・TRMS Voltage measurements 2-600V, Mains Frequency.
HELP            ・Display shows how to connect the instrument according to the function selected.
SPD             ・Surge Protection Device test, for SPD that uses varistor.
PAT             ・Portable Appliance Tester function, for Insulation and Protective conductor resistance test
SAFETY          ・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10. -
KEW6516BT
Read moreDISPLAY         ・Color LCD 3.5 inches dot matrix.
ATT             ・Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
                ・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOP            ・High test current range of 2Ω with 0.001Ω resolution.
                ・Zs Limit compares the values required by Electrical Installations Standard with
                 measured results.
RCD             ・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
                ・Single and Auto test, Ramp test and Contact voltage.
EARTH           ・Earth resistance test 2 and 3 wires with all accessories included.
INSULATION      ・Resistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITY     ・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATION ・On 3-phase lines with clear indication of the sequence on the display.
VOLTS           ・TRMS Voltage measurements 2-600V, Mains Frequency.
HELP            ・Display shows how to connect the instrument according to the function selected.
SPD             ・Surge Protection Device test, for SPD that uses varistor.
PAT             ・Portable Appliance Tester function, for Insulation and Protective conductor resistance test
Bluetooth        ・Communication by “KEW CONNECT”
SAFETY          ・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10.











