KEW4118
Read more• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 15mA LOOP measurement:
LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).
The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA).
• Direct reading of Prospective Short Circuit Current (PSC).
• Safe voltage measurement function.
• Large custom digital display readout on all models.
• Measure low loop resistances(resolution of 0.01Ω)
• Automatic lock-out if test resister overheats.
• Large custom digital display readout .
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating
• Complies with IEC 61557 -
KEW4140
Read more• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above.
• Dual Display allows simultaneous measurements like Loop & PFC/PSC.
• Two wire connection for Loop L-L, L-N and PSC testing is possible.
• Phase rotation, Voltage and Frequency measurements.
• Lock-down test button for ‘hands free’ testing with auto-start operation.
• Display and front panel keyboards with Backlight to be visible in dark places.
• Water and Dust proof (IP54) -
KEW4200
Read more• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display “NOISE” mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2Note:
A single earthing can not be measured. (Only for Multiple Earthing System) -
KEW4202
Read more• Real time measurements can be transferred, shown and saved on Android device (up to 100 measurements)
• Saved data includes measurement, GPS location and date & time Easy to check on map “When” and “Where” the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset valueEarth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments -
KEW4300
Read moreKEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.)
• 200/2000Ω (2 ranges): auto-ranging.
• Warning buzzer triggered at 100Ω or less.
• LED lights up when a large earth voltage is detected.
• Live circuit warning when 30V or higher voltage is detected. (KEW 4300 detects voltage even when measuring resistances.)
• LED light for illuminating measurement points.
(It turns on/off automatically in relation to the ambient brightness.)
• Small test current (max 2mA) not triggering RCD. -
KEW5010
Read more3 channel inputs for the simultaneous recording of Leakage Current and Load Current
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software “KEW LOG Soft 2” is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery) -
KEW5020
Read more3 channel inputs for the simultaneous recording of Leakage Current , Load Current and Voltage
• Power Quality analysis
• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current/voltage value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software “KEW LOG Soft 2” is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery) -
KEW5050
Read moreUnpreceded Ior Logger!
• Provides simultaneous measurements and logs up to 4 channels
• Supports various wiring systems (Single-phase 2&3-wire, Three-phase 3&4-wire)
• World’s fastest 200ms interval for leakage current measurement
• Offers both traditional leakage / load current measurements
• Large graphic display and magnet on the back case to attach it on metal enclosures -
KEW5406A
Read more• Custom microprocessor controlled for highest accuracy and reliability.
• 3 LEDs for checking correct wiring status.
• 0 and 180 degree phase angle switch permits quick tests and consistent readings.
• Digital read-out of tripping time.
• Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
• Large custom digital display readout.
• Visual indication of reversed phase and neutral wiring at socket.
• Designed to IP54 Rating.
• Complies with IEC 61557
• Test of a large kind of RCD’s: Standard, Selective, AC and A (DC sensitive breakers) -
KEW5410
Read more• Measurement of RCD trip time
 Conducting testing of rated residual non-operating currents at
 × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
 Measuring trip out current by varying current automatically.
• Remote Test
 Enabling a user to hold the Test Leads with his both hands
 by locking the Test Button. Measurement will automatically
 start when the main voltage is detected.
• Voltage Measurement
 Carrying out a constant measurement of voltage in the
 stand-by mode at each Range.
• Auto-detection of Contact voltage
 Detecting the voltage to earth of Earth electrodes or
 Protective conductors during RCD test – when applying
 test currents – at measurement using EARTH in order to
 prevent electrical shocks caused by the damaged earth.
 Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
 Dust- and Water-proof construction
 (designed to IEC 60529 IP54).
• Backlight
 Facilitating working at dimly illuminated locations.